Cold insulation

With cold insulation from Novisol, you protect your plant, prevent condensation and save energy sustainably – efficiently, in line with regulations and with lasting safety.

Technical highlights

Cold insulation places high demands on material choice, installation and resistance to vapour diffusion. Our solutions reliably meet all technical standards, tailored to each plant.

  • Precisely fitted insulation for every temperature range and geometry
  • Closed-cell insulation materials with high water vapour diffusion resistance
  • Optionally available with vapour-tight facing or special coating
  • Planning, material selection and installation all from a single source

Materials used in cold insulation

  1. 01

    Synthetic rubber (closed-cell)

    Fast, tool-free fitting – temperature-resistant up to approx. 240°C.

  2. 02

    Halogen-free synthetic rubber

    Halogen-free elastomeric foam with identical insulating performance. Suitable for areas with increased fire protection or sustainability requirements, such as Minergie-ECO.

  3. 03

    PUR spray foam

    Insulation material applied on site for complex geometries and special solutions. Offers high insulating performance, good adhesion and long-term dimensional stability.

  4. 04

    Polyisocyanurate (PIR) with plastic coating or facing

    PIR insulation shells with integrated vapour barrier or coating. Suitable for constant temperatures and applications with controlled moisture exposure.

  5. 05

    FOAMGLAS

    Non-combustible insulation material with high compressive strength and very high vapour diffusion resistance. Particularly suitable for industrial refrigeration and deep-freeze applications.

Components used in cold insulation

  1. 01

    Insulation tubes and sheets made of rubber

    Flexible moulded parts made of closed-cell elastomeric foam for building services installations. They reduce cold losses and prevent condensation forming on pipework and plant components.

  2. 02

    Solvent-free adhesives

    Special adhesives for permanent, air- and vapour-tight bonding of insulation materials. They ensure the function of the cold insulation system even under demanding installation conditions.

  3. 03

    Vapour barriers and facings

    Facings made of aluminium or PET, as well as sealants, prevent moisture ingress and ensure the insulating effect is maintained over the entire service life.

  4. 04

    Sheet-metal cladding

    Casings made of galvanised steel or stainless steel protect the insulation from mechanical impact and weathering, extending the service life of the system.

Certificates for insulation materials

Ecobau

Environmental assessment and verification of the ecological quality of the products used.

VKF technical assessment

Technical assessment of materials in accordance with the guidelines of the Association of Cantonal Fire Insurers (VKF).

Safety data sheet

Contains safety-relevant information on materials and their handling.

System approvals

Tested constructions in accordance with manufacturer approvals for various applications.

Installation instructions

Contain processing guidelines for professional, standard-compliant and durable installation.

Technical data

Thermal conductivity
  • λ -20 °C: 0.034 W/mK
  • λ 0 °C: 0.036 W/mK
  • λ +20 °C: 0.038 W/mK
  • λ +40 °C: 0.040 W/mK

according to EN 12667

Vapour diffusion resistance

μ ≥ 2'000

depending on the material used (rubber, FOAMGLAS, PIR)

Fire behaviour

Classification according to VKF:

  • RF1, RF2 or RF3
  • C-s2, d0 according to EN 13501 (Europe)
Insulation thickness

≥ 19

adapted to temperature, pipe routing and ambient conditions

Density

between 30 and 150 kg/m³

depending on the type of insulation material selected and the required stability

Ecology
  • halogen-free or halogen-containing
  • CFC- and HCFC-free
  • some variants available with ecobau certification

Applications

  • Air conditioning and refrigeration systems

    Cold insulation reduces energy losses and prevents condensation in air conditioning and refrigeration systems. It ensures consistently stable temperature control and improves operating efficiency. Image: from AI-generated images of application areas
  • Industrial plants

    In industry, cold insulation enables controlled processes by permanently keeping machines, pipes and plant within their optimal temperature range – regardless of ambient conditions.
  • Deep-freeze systems

    Deep-freeze systems in the food or pharmaceutical industry require precise temperature control. The insulation prevents energy losses and reliably protects against ice formation and moisture damage.
  • Sanitary installations

    For cold-water and rainwater pipes, cold insulation protects against condensation and corrosion. It prevents damage to building structures and significantly extends the service life of sanitary installations.
  • Ventilation systems

    Insulated ventilation ducts stay dry and efficient even with cold supply air flows. The insulation prevents condensation and ensures hygienic, energy-saving operation of the system.
  • District and local cooling networks

    In piped cooling systems, insulation ensures minimal temperature losses over long distances. This enables cost-effective energy supply across central cooling plants.

Questions and answers about cold insulation

The insulation thickness depends on the medium temperature. In building services, cantonal energy laws apply; in industry, standards such as TR BCI or project-specific calculations are often used.

This can only be determined through a specific heat calculation, as the medium, temperature and environment vary individually.

Yes. It reduces energy consumption and costs, improves safety and often meets normative requirements. It usually pays for itself within a short time.

Ja. PUR-Ortsschaum lässt sich direkt vor Ort applizieren und eignet sich besonders für komplexe Geometrien und schwer zugängliche Anlagenteile.

Novisol AG – your cold insulation partner

  • In-house production instead of subcontractors
  • Systematic bracket solutions
  • Damage repair as a basis of experience

System solutions with in-depth expertise

As one of the few providers in Switzerland, Novisol applies PUR spray foam on site itself – using three of its own machines. Thanks to specially developed bracket systems and daily experience in damage repair, we know the critical points of refrigeration systems. This knowledge feeds directly into the planning and implementation of your insulation.

Request a quote

Do you need a quote for industrial insulation, fire protection, ceiling or partition systems? Novisol prepares your quote quickly and precisely tailored to your project – with experience, care and technical expertise.

Quote request

References

  • Bell
    Basel and Oensingen
    Industrial insulation
    /
    Cold insulation
  • ENIWA Energiezentrale KSA Aarau
    Aarau
    Industrial insulation
    /
    Cold insulation
  • Galliker
    Bellinzona
    Industrial insulation
    /
    Cold insulation
  • Novartis WSJ 310
    Basel
    Industrial insulation
    /
    Cold insulation
    /
    Thermal insulation
  • Roche pRED
    Basel
    Industrial insulation
    /
    Thermal insulation
    /
    Cold insulation
    /
    Prefabrication