Thermal insulation

With high-quality thermal insulation, you reduce energy consumption, increase safety and extend the service life of your system – efficiently, sustainably and economically.

Technical highlights

Thermal insulation combines precisely manufactured components with standard-compliant insulation materials – efficient in terms of temperature control, installation and operating costs.

  • In-house sheet-metal production for precisely fitted solutions
  • Insulation material selected according to temperature range
  • Planning, calculation and installation from a single source
  • High-quality insulation even in confined spaces

Materials used in thermal insulation

  1. 01

    Mineral wool (stone wool)

    Extremely heat-resistant and non-combustible – ideal for industrial plants with high temperatures and safety-critical requirements. Insulation thickness freely selectable.

  2. 02

    Glass wool

    A non-combustible, cost-effective solution for many standard applications in building services and industry.

  3. 03

    Ceramic fibre

    Heat-resistant well beyond 1,000 °C, yet flexible and mouldable – perfect for complex geometries in high-temperature areas.

  4. 04

    Polyisocyanurate (PIR)

    Halogen-free insulation material with very good thermal conductivity, high dimensional stability and compressive strength – ideal for compact insulation thicknesses in heating and industrial applications.

  5. 05

    Ethylene propylene diene rubber (EPDM / synthetic rubber)

    Fibre-free, hygienic material – ideally suited for sensitive environments requiring dust-free, clean insulation and easy cleaning.

  6. 06

    Microtherm

    Ultra-thin silicate-based insulation material with extremely low thermal conductivity. Particularly suitable where space is limited and for special technical solutions.

  7. 07

    Aerogel

    This high-performance insulation material is processed in the form of pre-fabricated mats – ideal where space is limited and insulation performance requirements are high despite minimal thickness.

Components used in thermal insulation

  1. 01

    Sheet-metal cladding

    Individually manufactured sheet-metal cladding reliably protects the insulation from weather, mechanical impact and animal damage – for long-term safety and a neat appearance.

  2. 02

    Substructure

    We design and weld these in-house.

  3. 03

    Insulation materials

    For industrial applications with high temperatures – flexibly adaptable, non-combustible and, in combination with sheet-metal systems, particularly robust and durable.

    Insulation materials minimise heat flow and contribute to energy-efficient, economical, safe and comfortable plant operation.

  4. 04

    Fastening systems such as wire and tensioning straps

    Secure the insulation even under vibration or weather exposure. Individually selected according to medium, system and environment.

Certificates for insulation materials

System approvals

Tested constructions in accordance with manufacturer approvals for various applications.

Safety data sheet

Contains safety-relevant information on materials and their handling.

VKF technical assessment

Technical assessment of materials in accordance with the guidelines of the Association of Cantonal Fire Insurers (VKF).

Ecobau

Environmental assessment and verification of the ecological quality of the products used.

RAL quality mark for mineral wool

Quality seal for mineral wool products with tested properties.

Technical data

Thermal conductivity

Using mineral wool as an example (other insulation materials have differing values):

  • λ +50 °C: 0.039 W/mK
  • λ +100 °C: 0.045 W/mK
  • λ +200 °C: 0.064 W/mK
  • λ +300 °C: 0.092 W/mK

as per EN 14303:2009+A1:2013 (EN ISO 8497)

Maximum service temperature

Maximum operating temperature depends on the material.

Dimensional stability according to product specification.

Compressive strength

Depending on the material type (PIR, for example, offers high dimensional stability and compressive strength)

Density

Between 30 and 150 kg/m³, depending on the insulation material

Insulation thickness

Typical range: 20 to 160 mm (adjustable depending on application and calculation)

Fire behaviour group

Classification according to VKF: RF1, RF2 or RF3 (depending on the insulation material used)

Chloride release

Cl < 10 ppm according to EN 14303:2009+A1:2013 (EN 13468)

Moisture resistance

Using mineral wool as an example (other insulation materials have differing values):

  • Short-term water absorption WS, Wp ≤ 1 kg/m² according to EN 14303:2009+A1:2013 (EN 13472)

Areas of application

  • Heating systems

    In heating systems, thermal insulation prevents energy losses at pipework and fittings. This reduces energy consumption, ensures compliance with legal requirements and guarantees efficient heat distribution.
  • Industrial facilities

    In industrial production environments, thermal insulation protects plant components from energy loss. It improves energy efficiency, increases operational safety and supports cost-effective process control.
  • Steam systems

    In steam systems, thermal insulation reduces heat loss along the pipework. It protects against hot surfaces, lowers energy demand and ensures safe, standard-compliant operating conditions.
  • Power plants

    In power plants, thermal insulation protects pipework, boilers and units from energy loss. It improves efficiency, reduces heat radiation and supports compliance with safety-relevant standards.
  • Ventilation systems

    In ventilation systems, thermal insulation prevents energy loss, condensation and sound transmission. It ensures efficient air distribution and protects adjacent building components from moisture damage.
  • Sanitary installations

    In hot water and circulation systems, thermal insulation reduces heat loss. It helps you comply with drinking water regulations and energy laws, and increases the energy efficiency of the system.
  • Heat networks

    In district and local heating networks, thermal insulation ensures minimal energy losses in transported media. It helps optimise network efficiency and ensures compliance with energy standards.
  • Energy distribution tunnels

    In energy distribution tunnels, thermal insulation protects supply lines from energy loss and condensation. It enables low-maintenance systems and supports the separation of different media lines.

Questions and answers about thermal insulation

The insulation thickness depends on the medium temperature. In building services, cantonal energy laws apply; in industry, standards such as TR BCI or project-specific calculations are often used.

This can only be determined through a specific heat calculation, as the medium, temperature and environment vary individually.

Yes. It lowers energy consumption and costs, improves safety and often meets regulatory requirements. The investment usually pays off within a short time.

Novisol AG – your thermal insulation partner

  • In-house foam technology for precision
  • Expert planning support
  • Damage prevention through know-how

Experience, technology and safety

Novisol combines sound practical knowledge with technical expertise: our specialists provide support as early as the planning phase to avoid risks such as thermal bridges or design errors from the outset. With our own foam machines, we carry out precise insulation work directly on site – efficient, adaptable and durably effective.

Request a quote

Do you need a quote for industrial insulation, fire protection, ceiling or partition systems? Novisol prepares your quote quickly and precisely tailored to your project – with experience, care and technical expertise.

Quote request

References

  • Biomass plant Arlesheim
    Arlesheim BL
    Industrial insulation
    /
    Thermal insulation
  • Vahrn district heating plant
    South Tyrol, Italy
    Industrial insulation
    /
    Thermal insulation
  • Leibstadt, Gösgen, Beznau nuclear power plants
    Aargau / Solothurn
    Industrial insulation
    /
    Thermal insulation
  • Novartis WSJ 310
    Basel
    Industrial insulation
    /
    Cold insulation
    /
    Thermal insulation
  • Roche pRED
    Basel
    Industrial insulation
    /
    Thermal insulation
    /
    Cold insulation
    /
    Prefabrication